LR-FLEX300W

250W max power, 220W rated power.

Five protection: Overcurrent Protection, overvoltage protection, over-temperature protection, overpowerprotection, short-circuit protection

 

 

  

1.0   INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.1  VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

Min.

Normal

Max.

Unit

 

 

 

 

180

220

260

Vac

 

 

 

 

90

110

130

Vac

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.2   FREQUENCY

 

 

 

 

 

 

 

 

 

 

50/60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.3   CURRENT

 

 

 

 

 

 

 

 

 

 

 

Max. 3.5A /220Vac

 

 

Max. 7A /110Vac

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.4   INRUSH CURRENT

 

 

 

 

 

 

 

 

 

60A/220V at 25 COLD START   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5   EFFICIENCY

 

 

 

 

 

 

 

 

 

 

MIN  70%  AT FULL LOAD 220Vac 50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.0   OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.1  OUTPUT POWER

 

 

 

 

 

 

 

 

 

 

200W (MAX).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.2

VOLTAGE

 

 

 

 

 

 

 

 

 

 

+5V

+12V

-12V

+3.3V

+5Vsb

 

 

 

MAX LOAD

10A

9A

0.5A

8A

1.5A

 

 

 

MIN LOAD

1A

0.5A

0.1A

0.5A

0.1A

 

 

 

Regulation

± 5%

± 5%

± 10%

± 5%

± 5%

 

 

 

Ripple

50mV

120mV

300mV

50mV

50mV

 

 

 

Noise

100mV

240mV

360mV

100mV

100mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

1

The continuous max. DC output power shall not exceed 200W.And  +5V+3.3V total

 

 

 output power must not exceed 100W.

 

 

 

 

 

 

2

A 0.1uF ceramic disk capacitor & 10uF electrolytic (low ESR) capacitor should

 

 

 

 be put  across the output terminals during ripple & noise measure. The oscillo-

 

 

 

scope bandwidth set at 20MHz with  co-axial probe.

 

 

 

 

3

Regulation load must within 30% to 70% of maximum load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

AMBIENT TEMPERATURE 25.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.0   PROTECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1 OVER LOAD PROTECTION

 

 

 

 

 

 

 

3.1.1  120-160% of maximum power.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.2 SHORT CIRCUIT PROTECTION

 

 

 

 

 

 

All output to ground.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE :  After protection active all output will shut down .After shut down the power supply shall

 

 

 

return to normal operation.only after the fault has been removed and the remote signal

 

 

 

reset for a minimum 1 second (or the AC remove for 10 second).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.0   TIMING SEQUENCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.1

TURN ON TIME

 

 

 

 

 

 

 

 

 

900mS MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.2

P.G Delay time

 

 

 

 

 

 

 

 

 

100~500mS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.3

P.F time

 

 

 

 

 

 

 

 

 

1mS MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.4

Hold up time.

 

 

 

 

 

 

 

 

 

15mS MIN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.0   TEMPERATURE CHARACTORISTICS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.1   OPERATION AMBIENT :

 

 

 

 

 

 

 

+10 to +40℃。

 

 

 

 

 

 

 

 

20~85%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.2   NON-OPERATION AMBIENT:

 

 

 

 

 

 

-40 to +70℃。

 

 

 

 

 

 

 

 

10~90%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.0   SAFETY REQUIREMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.1   HI-POT TEST

 

 

 

 

 

 

 

 

 

Vac =1500 Vac Current limit 10mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.2   GROUNDING TEST

 

 

 

 

 

 

 

 

 

R< 100mOhm

 

Condition

I=24Aac

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.3    Isolation test

 

 

 

 

 

 

 

 

 

 

R>2MOhm

 

Condition

400VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.0

ELECTROMAGNETIC COMPATIBILITY (Optional )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.1

Meet with the EMI standards.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.0

Burn-in

 

 

 

 

 

 

 

 

 

 

Full load,2 Hour .

 

 

 

 

 

 

 

 